Reactance electrical engineering
WebThis tool is designed to calculate the reactance and admittance of an inductor if its inductance and the frequency of the supply voltage is given. This calculator can also calculate the inductance of an inductor if the reactance and frequency of the supply voltage is known. Note that the input inductance should be in nano henries (10 -9 H). WebHowever, emulated reactance and resistance by SSSC – ES is likely to affect the performance of a distance protection system. This paper presents a detailed model of an SMIB system with SSSC – ES. Injected voltage by SSSC – ES in all the four quadrants of operation is presented. ... JF - International Journal of Electrical and Computer ...
Reactance electrical engineering
Did you know?
WebReactance, denoted X , is a form of opposition that electronic components exhibit to the passage of alternating current (alternating current) because of capacitance or inductance. … WebEngineering Electrical Engineering A hydro powered 50 MVA generator, with a synchronous reactance 0.33 p.u., delivers 40 MW over a transmission line of 0.15 p.u. reactance to an infinite system. A 3-phase short circuit transient fault occurs on the busbar between the generator and transmission line. Given that the generator emf is 1.4 p.u. prior to and …
WebReactance is defined as the RATIO of MAXIMUM VOLTAGE to MAXIMUM CURRENT, within each ( applied ) sine wave cycle... For a capacitor, maximum VOLTAGE occurs at w = +1/4 cycle, when SIN (w) = +1, and …
WebIn the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to the other. WebReactance definition, the opposition of inductance and capacitance to alternating current, expressed in ohms: equal to the product of the sine of the angular phase difference …
WebApr 17, 2024 · Reactance (also known as electrical reactance) is defined as the opposition to the flow of current from a circuit element due to its …
WebFeb 24, 2012 · When a circuit consist of Resistance and Inductance reactance in series is considered as shown below. When the circuit consist of Resistance and Capacitive reactance in series is considered as shown below. Admittance of a Parallel Circuit A circuit which consist of two branches say A and B are considered as shown in figure below. ravichandran ashwin highest scoreWebQ4: A 50 Hz, 11KV, 3-ph, alternator with earthed neutral has a reactance of 5 Ω\ ph and is connected to bus bar through a C.B. The distributed capacitance up to C.B between phase and neutral is 0.01μF, determine: 1-the recovery voltage across the contacts of the breaker, 2-the frequency of oscillation, 3- The restriking voltage across the contacts of the breaker, … simplebean cannot be resolved to a typeWebMay 16, 2016 · If the load is a pure reactance, the voltage across it is 90° out of phase with the current. However, if the wire is a pure resistance, then the voltage across it must be in-phase with the current. ravichandran ashwin houseWebReactance is defined as the imaginary part of electrical impedance, and is analogous to but not generally equal to the negative reciprocal of the susceptance – that is their … ravichandran ashwin ipl auctionWebEngineering Electrical Engineering 3) The longitudinal synchronous reactance of a salient pole synchronous generator is 0.8 pu, the transverse synchronous reactance is 0.3 pu, and the stator winding resistance is 0.04 pu. While the generator is operating at rated voltage and full load with a capacitive power factor of 0.8; a-) Calculate the ... simple beam patio coversWebMar 30, 2024 · Formulas An impedance Z comprising a resistance R in series with a reactance X can be converted to an admittance Y comprising a conductance G in parallel with a susceptance B: Y = Z -1 = 1 / (R + jX) = (R – jX) / (R2 + X2) = R / (R2 + X2) – jX / (R2 + X2) = G – jB G = R / (R2 + X2) = R / Z 2 B = X / (R2 + X2) = X / Z 2 simple beam stress calculatorWebPercentage Resistance, Reactance & Impedance: Transformer Efficiency: Efficiency At Any Load: All Day Efficiency: Condition For Maximum Efficiency: Load Current For Maximum Efficiency: EMF Induced In Primary & Secondary Windings: Where E1 = EMF induced in primary winding E2 = EMF induced in Secondary winding N1 = Number of Turns in Primary … ravichandran ashwin debut